Welcome to Hami Medical, your trusted source for high-quality used X-ray machines for sale. We offer an extensive selection of refurbished X-ray systems from top brands, ensuring you get the best value for your investment. Whether you need digital or analog X-ray machines, we have the right equipment to meet your medical facility’s needs.
|
|
|
|
|
|
 |
|
Brand: GE Healthcare Model: AMX III Portable
- Power: Obtained from rechargeable 120V battery
- Motor drive ratings: The drive assist unit can be driven at speeds up to 180 feet per minute or 54.9 meters per minute
- X-ray generator ratings and duty cycle: All radiographic exposures with this unit are at 100 mA
- kVp (maximum): 110 to 125 –95 • mAs (maximum):200 –250 –320 • Typical accuracy: ±6% of kVp – ±10% of mAs
- Conditions to meet previously mentioned accuracy
- Handswitch must have been released for 25 seconds after previous exposure.
- 15-minute interval after change completion with keyswitch in ON or CHARGE.
- Main power circuit breaker ON must be allowed before making an exposure
- Minimum inherent filtration is 1.5 mm aluminum equivalent to 150 kVp. Additional filtration may be obtained by inserting 1 mm and/or 2 mm aluminum filters.
- rage at 40” source to image distance is provided for tubes with a 15-degree target angle.
- Collimator can be rotated and locked positively at 0º, ±15º, ±30º, ±45º, and ±90º from the front position.
|
|
| |
———————————————— |
|
————————————————————————————– |
|
|
 |
|
Brand: GE Healthcare Model: AMX-4 Portable
- kVp: 50 to 76 in 2kVp steps • 80 to 125 in 5kVp steps
- Tube Height In (transport look over): 131.8 cm (51.9 in.) • mA: 100 mA nominal
- Digital readouts, blue vacuum fluorescent. • Top: 1.9 cm (3/4 in.) kVp and mAs.
- Message: 0.95 cm (3/8 in.) all message. • Battery Status: 0.95 cm (3/8 in.) bar graph.
- Switches are dome-type push buttons under mylar cover.
- On/Off Two Position Switch: -Off/Remove – Key -Off / -On
- The drive System and X-ray work only in ON position. Charger works in either position.
- Hand switch controls the rotor prep, exposure and remote field light.
- Audible Tone: X-ray On Generator
- Frequency: 1,000 Hz • Voltage: 50 to 125 kVp • Power: 12.5 kW nominal
- Cables: Vinyl covered, rated to 75 kVp each or 150 kVp for pair. Federal type connectors.
- Speed, Arm Out of Transport Position: 2.4 kph (1.5 mph). liquid” or film electrolyte technology classifies battery as dry. Cannot leak if punctured.
- Pack: Nine 12-volt packs connected in series (108 V nominal). Runs both motor drive and X-ray from same pack.
- Contact Us For Price
|
|
| |
———————————————— |
|
————————————————————————————– |
|
|
 |
|
Brand: GE Healthcare Model: Proteus XR/a
• Full-featured radiographic system designed to meet the needs of any facility’s imaging workload.
• Configurable unit for clinical flexibility. • Produces impressive image quality at reasonable dose levels.
• Four-way floating tabletop for convenient patient positioning.
• Rotating overhead tube support can be adjusted for off-table, upright radiography, or stretcher cases.
• Cushioned tabletop bumpers help to eliminate sharp corners.
• Adjustable table height for additional patient comfort with getting on and off the table.
• Three-phase, high-frequency generator self-calibrates for accurate, short, virtually ripple-free output for dose-efficient exposures.
• High-speed x-ray tube offers focal spots of 0.6mm and 1.2mm.
• High-resolution touchscreen offers simultaneous display of all relevant technique factors.
• Clearly displayed parameters, including kV, mAs, SID and angle.
• Auto-collimators include cassette-size sensing trays.
|
|
|
|
|
————————————————————————————– |
|
|
 |
|
Brand: SHIMADZU Model: Mobile Art Evolution
- Nominal Focal Spot Size: 0.7/1.3 mm.Target Angle: 16 degrees • Nominal Max. Tube Voltage Radiography:133 kV
- Max. Anode Heat Content: 300 kHU. • Max. Anode Heat Dissipation Rate: 1130 HU/s
- Max. Continuous Heat Dissipation Rate: 300HU/s • Nominal anode input power (20 msec, 0.1msec)
- Focus size 1.3 mm: 36.4 kW. • Focus size 0.7 mm: 19.9 kW.
- Anode rotation: RPM at 70 Hz: 3800 rpm or more. • RPM is 60 Hz: 3200 rpm or more.
X-ray Tube Support and Cart Specification
- Driving method: Motorized • Maximum Driving Speed: Approx. 5 km/h.
- Height during transportation: Approx.1930 mm. • Focal point height (from floor): Approx.600 to 2010 mm.
- Tube support arm: Telescopic arm. • Arm length: 635 to 1200 mm. • Column rotation range: +/- 270 degree.
- Tube rotation around support arm: +/- 180 degree. • Tube rotation around tube axis: Forward 90°, Backward 20°.
- Rotation of collimator: +/- 110 degree. • System width x length: 580 mm x 1145 mm.
- Contact Us For Price
|
|
| |
———————————————— |
|
————————————————————————————– |
|
|
 |
|
Brand: AGFA Model: DX D100
- Fast assessment of images after exposure
- Improved patient comfort
- Increased productivity, for lower cost per exam
- Higher image quality, for improved diagnostic effectiveness
- Dose reduction potential for all users
- Easy to operate and position both precisely and safely, with portable DR detector and motorizedcontrol
- MUSICA2processing for superior contrast detail and exam-independent, consistent image quality
- Excellent connectivity to PACS, HIS/RIS and imagers
- Highly effective generator power, for shorter exposure times and sharper images
- Efficient battery capacity due to separate battery
- Contact Us For Price
|
|
| |
———————————————— |
|
————————————————————————————– |
|
|
 |
|
Brand: SIEMENS Model: Mobilett XP
- X-ray tube: Features a 30 kW generator with rotating anode technology to ensure efficient operation and performance.
- Detector: A CCD (charge-coupled device) detector with a resolution of 2048 x 2048 pixels is used, which ensures high image quality.
- Image processing: The device utilizes image processing technologies such as dynamic range control (DRC), real-time contour enhancement, automatic brightness control (ABC), and automatic dose control (ADC). These features help to improve image quality and reduce radiation dose.
- Mobile device: The Siemens Mobilett XP Digital has a built-in battery and motorized drive that makes it easy to move and position the device. It is also equipped with four rotating casters for easy movement.
- Collimator: The device has automatic and manual collimation modes with the function of centering the light beam. This allows for precise positioning of the X-ray beam and provides more accurate images.
- User interface: There is a touch control panel with an intuitive interface for user convenience.
- Image storage: The device has digital image storage with a capacity of up to 50,000 images.
- Connectivity: Siemens Mobilett XP Digital supports the DICOM 3.0 standard, has Ethernet and USB support, which allows you to conveniently connect the device to other medical devices and systems.
- Protection against radiation: Different levels of radiation protection are available to protect patients and operators.